Problem 99

Question

Americium-241 is used in smoke detectors. It has a first-order rate constant for radioactive decay of \(k=1.6 \times 10^{-3} \mathrm{yr}^{-1}\). By contrast, iodine-125, which is used to test for thyroid functioning, has a rate constant for radioactive decay of \(k=0.011\) day \(^{-1}\). (a) What are the half-lives of these two isotopes? (b) Which one decays at a faster rate? (c) How much of a \(1.00\)-mg sample of each isotope remains after 3 half-lives? (d) How much of a 1.00-mg sample of each isotope remains after 4 days?

Step-by-Step Solution

Verified
Answer
a) The half-lives of Americium-241 and Iodine-125 can be calculated as \(t_{1/2(Am-241)} = 433.5 \, \mathrm{yr}\) and \(t_{1/2(I-125)} = 63.1 \, \mathrm{days}\), respectively. b) Iodine-125 decays at a faster rate since its rate constant (\(0.011 \mathrm{day}^{-1}\)) is higher than that of Americium-241 (\(1.6 \times 10^{-3} \mathrm{yr}^{-1}\)). c) After 3 half-lives, the remaining amount of both Americium-241 and Iodine-125 will be \(0.125 \, \mathrm{mg}\) each. d) After 4 days, the remaining amount of Americium-241 is approximately \(0.994 \, \mathrm{mg}\), and the remaining amount of Iodine-125 is approximately \(0.641 \, \mathrm{mg}\).
1Step 1: Half-life Formula for First-Order Decay Process
The half-life formula for a first-order decay process is given by: \(t_{1/2} = \frac{\ln{2}}{k}\), where \(t_{1/2}\) is the half-life and \(k\) is the first-order rate constant.
2Step 2: (a) Calculate half-lives of the isotopes
Using the given rate constant values, we will calculate the half-lives of both isotopes. For Americium-241 (\(k = 1.6 \times 10^{-3} \mathrm{yr}^{-1}\)): \(t_{1/2(Am-241)} = \frac{\ln{2}}{1.6 \times 10^{-3} \mathrm{yr}^{-1}}\) For Iodine-125 (\(k = 0.011 \mathrm{day}^{-1}\)): \(t_{1/2(I-125)} = \frac{\ln{2}}{0.011 \mathrm{day}^{-1}}\) Calculate these to find the half-lives.
3Step 3: (b) Determine which isotope decays faster
Compare the rate constants of the two isotopes to determine which one decays at a faster rate. The isotope with the higher rate constant decays faster.
4Step 4: (c) Calculate remaining amount after 3 half-lives
To calculate the remaining amount of each isotope after 3 half-lives, we will apply the following formula: Remaining amount = Initial amount × \((\frac{1}{2})^n\), where n = number of half-lives. For Americium-241: Remaining amount = 1.00 mg × \((\frac{1}{2})^3\) For Iodine-125: Remaining amount = 1.00 mg × \((\frac{1}{2})^3\) Calculate the remaining amount for both isotopes after 3 half-lives.
5Step 5: (d) Calculate remaining amount after 4 days
To calculate the remaining amount of each isotope after 4 days, we will use the formula: Remaining amount = Initial amount × \(e^{-kt}\), where t = time elapsed. For Americium-241: Remaining amount = 1.00 mg × \(e^{-(1.6 \times 10^{-3} \mathrm{yr}^{-1})(\frac{4 \, \mathrm{days}}{365.25 \, \mathrm{days/yr}})}\) For Iodine-125: Remaining amount = 1.00 mg × \(e^{-(0.011 \mathrm{day}^{-1})(4 \, \mathrm{days})}\) Calculate the remaining amount for both isotopes after 4 days.

Key Concepts

First-Order KineticsHalf-Life CalculationIsotope ComparisonAmericium-241Iodine-125
First-Order Kinetics
In the world of chemistry, first-order kinetics is a fundamental concept, especially when discussing radioactive decay. A first-order decay process is characterized by the rate of change in the number of undecayed nuclei being proportional to the number of undecayed nuclei present. This means the decay process depends only on the amount present, not on any initial conditions or the passage of time.
For first-order reactions, one fascinating consequence is that they follow an exponential decay model. The mathematical representation is given as:
  • \[ \frac{dN}{dt} = -kN \ \] where \( N \ \) is the number of undecayed nuclei, \( \frac{dN}{dt} \ \) is the rate of decay, and \( k \ \) is the rate constant.
This formula helps us understand how substances decrease over time, providing the backbone for calculating half-lives and understanding radioactive processes.
Half-Life Calculation
The half-life of an isotope is a crucial concept in understanding radioactive decay. It's the time required for half of the radioactive nuclei in a sample to decay. This concept allows scientists to gauge how stable and long-lasting a radioactive substance might be.
For first-order kinetics, the half-life is determined using the formula:
  • \[ t_{1/2} = \frac{\ln{2}}{k} \]
Where \( t_{1/2} \ \) is the half-life and \( k \ \) is the first-order rate constant. This equation illustrates that the half-life is inversely related to the rate constant, meaning a higher rate constant results in a shorter half-life.
So for Americium-241 with a rate constant of \(1.6 \times 10^{-3} \mathrm{yr}^{-1}\), its half-life will be different compared to Iodine-125's \(0.011 \mathrm{day}^{-1}\). Calculating the half-life provides insights into how quickly each isotope reduces to half its original quantity.
Isotope Comparison
When comparing isotopes, understanding their rate constants and half-lives reveals significant characteristics about how they behave. Two isotopes with different rate constants will decay at different speeds, impacting their practical uses.
Americium-241, used in smoke detectors, is relatively stable with a smaller rate constant compared to Iodine-125. This means it has a longer half-life, ideal for consistent long-term performance in devices like smoke detectors. In contrast, Iodine-125 decays much faster, making it suitable for medical applications where rapid decay is beneficial.
So when comparing these isotopes:
  • Americium-241 has a longer half-life, making it practical for long-term use.
  • Iodine-125, with a shorter half-life, is apt for quick tests in medical fields.
This comparison showcases how understanding decay kinetics aids in selecting the appropriate isotope for specific applications.
Americium-241
Americium-241 is a synthetic radioactive isotope notable for its use in commercial smoke detectors. It undergoes alpha decay and emits ionizing radiation, which interacts with the smoke particles that enter the smoke detector. The rate constant for americium-241 is given as \(1.6 \times 10^{-3} \mathrm{yr}^{-1}\), suggesting a slow decay process.
This slow degradation is advantageous because it ensures the longevity of the smoke detector without frequent replacements. Americium-241's long half-life aligns well with this usage, providing reliability over years of use.
In summary, the characteristics of americium-241, such as its rate constant and half-life, make it uniquely suited for applications requiring stability and longevity.
Iodine-125
Iodine-125 is a radioactive isotope used primarily in medical diagnostics, particularly for thyroid function tests. With a rate constant of \(0.011 \mathrm{day}^{-1}\), it decays relatively quickly, making it ideal for applications that require rapid decay and short-term use.
The half-life of iodine-125, derived from its rate constant, means it maintains usefulness over a shorter period, which is perfect for medical conditions needing timely diagnostic results.
In medical tests, such as those for the thyroid, it effectively provides feedback on organ performance without exposing patients to long-lasting radiation. This quick action, thanks to its high rate constant, aligns with the need for fast results in healthcare environments.